BSSHM - THERMAL (THR) BATTERY
- MSDS: BSSHM
- Manufacturer: NOT KNOWN SUPPLIED BY US ARMY MISSILE COMMAND
- Product Name: THERMAL (THR) BATTERY
- National Stock Number: 6135-00-237-1703
Product Identification
Product ID:THERMAL (THR) BATTERY
MSDS Date:11/30/1992
FSC:6135
NIIN:00-237-1703
MSDS Number: BSSHM
Responsible Party
REDSTONE ARSENAL, AL 35809
US
Emergency Phone: CECOM (908) 544-3112
Info Phone: CECOM (908) 544-3112
Preparer: CECOM SAFETY OFFICE
Cage: KO765
Contractor
Telephone: 201-945-5766
Cage: 18876
Ingredients
CALCIUM
CAS: 7440-70-2
RTECS: EV8040000
Fraction By Weight: < 10%
CALCIUM CHROMATE (SARA III)
CAS: 13765-19-0
RTECS: GB2750000
Fraction By Weight: <10%
OSHA PEL 0.05 MG (CR)/M3
ACGIH TLV: 0.001 MG/M3, A2;9394
EPA Report Quantity: 10 LBS
DOT Report Quantity: 10 LBS
POTASSIUM PERCHLORATE
CAS: 7778-74-7
RTECS: SC9700000
Fraction By Weight: < 10%
ASBESTOS (FRIABLE) (SARA III)
CAS: 1332-21-4
RTECS: CI6425000
Fraction By Weight: < 1%
OSHA PEL SEE 1910.1001
ACGIH TLV: 0.2 - 2 FIBER/CC; 94
EPA Report Quantity: 1 LB
DOT Report Quantity: 1 LB
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:INTACT BATTERERIES PRESENT NO SPECIFIC
HAZARDS. BURNING BATTERIES EMIT TOXIC FUMES. LEAKING BATTERY
MATERIAL IS IRRITATING TO SKIN.
Explanation of Carcinogenicity:CONTAINS ASBESTOS & CALCIUM CHROMATE
[1332-21-4] WHICH IS LISTED BY NTP AND IARC AND REGULATED BY OSHA
AS A CARCINOGEN.
Effects of Overexposure:INHALATION OF FUMES OF BURNING BATTERIES MAY
CAUSE SEVERE RESPIRATORY IRRITATION. EXPOSURE TO LEAKING BATTERY
MATERIAL MAY CAUSE SEVERE IRRITATION TO SKIN/EYES.
Medical Cond Aggravated by Exposure:BURNING BATTERIES: RESPIRATORY
AILMENTS, LEAKING BATTERIES: SKIN CONDITIONS.
First Aid
First Aid:IF BATTERY CONTENTS COME IN CONTACT W/THE BODY. WASH AFFECTED
AREA FOR AT LEAST 15 MIN W/CLEAN H20. DO NOT ATTEMPT TO
NEUTRALIZE. SEEK MEDICAL ATTENTION.
Fire Fighting
Extinguishing Media:CARBON DIOXIDE OR DRY CHEMICAL FIRE EXTINGUISHER
10-B:C.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE SELF-CONTAINED
BREATHING APPARATUS. BATTERY/CELLS MAY RUPTURE AND/OR RELEASE
TOXIC FUMES, IF SUBJECT TO FIRE HEAT.
Unusual Fire/Explosion Hazard:FIRE MAY CAUSE BATTERIES TO FUME
Accidental Release
Spill Release Procedures:AVOID SKIN, EYE CONTACT. USE NON-FLAMMABLE
ABSORBENT MATERIAL FOR CLEAN UP. COORDINATE W/INSTALLATION SAFETY
AND ENVIRONMENTAL OFFICES.
Neutralizing Agent:NONE SPECIFIED
Handling
Handling and Storage Precautions:DO NOT ABUSE BATTERIES. WHEN STORING
BATTERIES, STORE IN A COOL, DRY & WELL VENTILATED AREA WHICH HAS
BEEN APPROVED BY THE LOCAL FIRE DEPARTMENT.
Other Precautions:DO NOT ATTEMPT TO RECHARGE. BATTERIES MUST BE FIRED
PRIOR TO DISPOSITION. WHEN ACTIVATED, BATTERY SURFACE TEMPERATURES
CAN EXCEED 500 DEGREES F.
Exposure Controls
Respiratory Protection:CONTACT LOCAL SAFETY/INDUSTRIAL HYGIENE OFFICE
TO DETERMINE IF RESPIRATORY PROTECTION IS REQUIRED . IF BATTERIES
ARE BURNING USE SCBA.
Ventilation:CONTACT LOCAL SAFETY/INDUSTRIAL HYGIENE OFFICE TO DETERMINE
IF LOCAL EXHAUST VENTILATION IS NEEDED
Protective Gloves:CHEMICAL AND THERMAL RESISTANT GLOVES
Eye Protection:CHEMICALLY RESISTANT SPLASH GOGGLES
Other Protective Equipment:CHEMICAL RESISTANT APRON
Work Hygienic Practices:WHEN DEACTIVATION THRMAL BATTERY, PROTECT HANDS
W/THERMAL/CHEMICAL GLOVES, PLACE BATTERY ON HEAT/FIRE RESISTANT
SURFACE.
Supplemental Safety and Health
THIS MSDS WAS CODED FROM A MSDS THAT CECOM SAFETY OFFICE CREATED.
(908) 544-3112
Chemical Properties
NRC/State Lic Num:NOT KNOWN
Stability
Stability Indicator/Materials to Avoid:YES
STORE SEPARATELY FROM OTHER HARADOUS MATERIALS AND GAIN LOCAL FIRE
DEPARTMENT APPROVAL FOR STORAGE AREAS.
Stability Condition to Avoid:NOT STATED BY MANUFACTURER, ASSUME FIRE,
HIGH HEAT
Hazardous Decomposition Products:BURNING BATTERIES MAY RUPTURE AND/OR
EMIT TOXIC FUMES.
Disposal
Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH ALL
APPLICABLE LOCAL, STATE AND FEDERAL REGULATIONS. COORDINATE WITH
SUPPORTING INSTALLATION AND/OR MACOM ENVIRONMENTAL OFFICE PRIOR TO
DISPOSAL
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.